Informix ODBC Driver Version 4.10.UC12, HP Itanium 32bit

                      =================================
                            MACHINE SPECIFIC NOTES
                                    FOR
              HCL Informix-CLIENT SDK 4.10.UC12 PRODUCT RELEASE
                    HCL Informix ODBC Driver Version 4.10.UC12
                              On HP Itanium 32bit
                               DATE: 25 Jun 2018
                      =================================

OS Information : Built on HP-UX 11i V3 (aka 11.31) Itanium.

Machine Specific Notes
======================

1. This product was built on HP-UX 11i V3 (aka 11.31) Itanium using the 
   following compilers:

   HP C/aC++ B3910B A.06.26 [Apr 12 2011]

   and with the following packages: 

   Bundle Name     Description
   -----------     -----------
   B9007AA         C.11.31.06     HP C/aC++ Developer's Bundle
   BUNDLE          B.2011.08.04   Patch Bundle

2. For shared library support, environment variable SHLIB_PATH needs to be set
   to include the $INFORMIXDIR/lib/cli directories where INFORMIX ODBC 
   shared libraries are installed.

   (for Bourne or Korn Shell)
   SHLIB_PATH=$INFORMIXDIR/lib/cli:$INFORMIXDIR/lib/esql:$SHLIB_PATH
   export SHLIB_PATH

   (for C Shell)
   setenv SHLIB_PATH $INFORMIXDIR/lib/cli:$INFORMIXDIR/lib/esql:$SHLIB_PATH

3. The thread safe INFORMIX ODBC libraries are supported for the current 
   release.

4. Pluggable Authentication Module (PAM)

   PAM functionality is supported on HP-UX operating systems. The PAM is 
   dependent on the libpam.so library supplied by the Operating System vendor.

   Use of PAM can be enabled or disabled by the system administrator. By 
   default, IBM IDS will use the traditional authentication mechanism in 
   order to avoid widespread changes required by the users.

   The PAM service identifies the PAM module. This PAM module typically
   resides in /usr/lib/security and its parameters are listed in
   /etc/pam.conf.

5. IPv6 Support 

   The product supports Internet Protocol Version 6 (128 Bit Internet Addresses)
   as well as IPv4 (32 Bit Addresses).

   In order for the machine name specified in the SQLHOSTS file to resolve
   to the correct IP address, the name services files on the Operating System
   should be correctly configured. If the machine has IPv6 address configured
   and the listener thread is bound to an IPv6 address, then the name
   resolution files /etc/netsvc.conf should be configured to fetch IPv6
   address. Also use the appropriate /etc/hosts setting if local machine
   settings are used.

   For compatibility with older IBM Informix client and server products,
   assign the same hostname with both an IPv4 address and an IPv6 address.
   If the listener needs to be bound to an IPv4 address and the name services
   resolve the name in the order of the IPv6 address followed by IPv4 address,
   then an explicit IPv4 address needs to be put in nodename field of SQLHOSTS
   file. Client applications should also use the same setting.

Check the following web site for the latest HP-UX system requirements:

   http://www-01.ibm.com/support/docview.wss?rs=630&uid=swg27016673


(C) Copyright IBM Corp. 2002, 2017
(C) Copyright HCL Technologies Ltd. 2018. All Rights Reserved.








Copyright© 2020 HCL Technologies Limited