C++ Interface Version 4.10.UC11, HP Itanium 32bit

                      =================================
                            MACHINE SPECIFIC NOTES
                                    FOR
               HCL Informix-Client SDK 4.10.UC11 PRODUCT RELEASE
                           C++ Interface Version 4.10.UC11
                              On HP Itanium 32bit
                               DATE: 15 Mar 2018
                      =================================

OS Information : Built on HP-UX 11i V3 (aka 11.31) Itanium.

Machine Specific Notes
======================

1. This product was built on HP-UX 11i V3 (aka 11.31) Itanium using the 
   following compilers:

   HP C/aC++ B3910B A.06.26 [Apr 12 2011]

   and with the following packages: 

   Bundle Name     Description
   -----------     -----------
   B9007AA         C.11.31.06     HP C/aC++ Developer's Bundle
   BUNDLE          B.2011.08.04   Patch Bundle

2. For shared library support, setting the environment variable 
   SHLIB_PATH:

     (for C Shell)
     setenv SHLIB_PATH $INFORMIXDIR/lib:$INFORMIXDIR/lib/esql:
     $INFORMIXDIR/lib/c++:$INFORMIXDIR/lib/dmi:$SHLIB_PATH

     (for Bourne or Korn Shell)
     SHLIB_PATH=$INFORMIXDIR/lib:$INFORMIXDIR/lib/esql:
     $INFORMIXDIR/lib/c++:$INFORMIXDIR/lib/dmi:$SHLIB_PATH
     export SHLIB_PATH 

3. To build any C++ application that uses the "Standard Template Library",
   the C++ compiler flag "-AA" is required.

4. IPv6 Support 

   The product supports Internet Protocol Version 6 (128 Bit Internet Addresses)
   as well as IPv4 (32 Bit Addresses).

   In order for the machine name specified in the SQLHOSTS file to resolve
   to the correct IP address, the name services files on the Operating System
   should be correctly configured. If the machine has IPv6 address configured
   and the listener thread is bound to an IPv6 address, then the name
   resolution files /etc/netsvc.conf should be configured to fetch IPv6
   address. Also use the appropriate /etc/hosts setting if local machine
   settings are used.

   For compatibility with older IBM Informix client and server products,
   assign the same hostname with both an IPv4 address and an IPv6 address.
   If the listener needs to be bound to an IPv4 address and the name services
   resolve the name in the order of the IPv6 address followed by IPv4 address,
   then an explicit IPv4 address needs to be put in nodename field of SQLHOSTS
   file. Client applications should also use the same setting.

Check the following web site for the latest HP-UX system requirements:

   http://www-01.ibm.com/support/docview.wss?rs=630&uid=swg27016673